12/11/2022 0 Comments Pfe automailer servicing![]() ![]() Warning: High voltage PC always live unless isolated at wall.ġ. Protective cover over fuses and mains cables. The main fuses are protected by a further cover, as shown below. To gain access, remove the outer cover below the envelope feeder, then the cover panel inside. DIN rail fuses The mains supply from the mains switch (see above) is connected to the main 30A fuses, located on a DIN rail with all other fuses at the rear of the insert head, below the envelope feeder. The cables exiting at the bottom of the switch are connected to the DIN rail fuses, as described below. Observe the polarity of the incoming mains cables - the brown cable (line) connects to L1, the blue cable (neutral) connects to N (note that colours may vary depending on locality). ![]() To gain access, remove the outer cover, then the plate holding the switch. Incoming Mains Connections The mains is connected to the isolator switch located at the rear of the insert head, above the wetter fluid bottle. If 2 x Hi-Cap Folders, a Hi-Cap and a Lo-Cap Folder or an OMR/Barcode Folder with any other unit are located next to each other on the same track pair, it is necessary to order and fit an additional power supply kit 184-156 to ensure correct operation. Changing the supplied plug must be carried out by a qualified electrician. Changing the supplied plug negates any responsibility of the Company for the safety integrity of the machine. #Pfe automailer servicing free#Input Voltage 230v 50/60Hz (± 10% maximum) Power Connector Machine fitted with BS4343 32A IP44 industrial free plug connector, conforming to EN60309 1 & 2 and CEE17. Mains wiring should not normally need attention and unless there is a specific reason, it should not be changed. ![]() PUT SAFETY FIRST! The following electrical information for the incoming mains supply on the 1000/1200 must be noted. Before switching the machine back on after completion of maintenance work, ensure all external covers are in place and undamaged.The panel must always be replaced when maintenance work is completed. Failure to isolate the mains could result in death or injury! The DIN rail is protected by an inner safety panel, retained along its top edge by 2 screws. If it is intended to access the mains distribution DIN rail behind the insert head, the machine must be isolated from the mains supply.To switch this off also, the power cable must be isolated from the incoming supply by switching off at supply source. Turning the switch does not isolate the PC from mains supply, which is left on for access to technical documentation. Switch the machine OFF by turning the isolator switch on the rear of the insert head cover to the ‘off’ position. #Pfe automailer servicing manual#Page Safety Notes, Power Source & Labels 3.2ĭS-1200 G3 Service Manual CAUTION! Prior to carrying out any maintenance procedures on the machine, the following safety precautions must be observed: ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |